# Victron Settings Rotary switch vs App: last setting change wins [SmartSolar](https://battlebornbatteries.com/charging-battleborn-lifepo4-batteries/ ) [SmartBMV](https://battlebornbatteries.com/configure-victron-bmv-700-bluetooth-dongle/ ) [relay](https://battlebornbatteries.com/charging-battleborn-lifepo4-batteries/ ) [Lead Acid](https://www.victronenergy.com/media/pg/SmartShunt/en/all-features-and-settings.html ) | 100Ah 12V LiFePO4 | 2x | |--------------------------|----------| | SmartSolar | MPPT | |--------------------------|----------| | Rotary switch | 7 | * Leave at 2 and set with App | Battery voltage | 12V | | Max charge current | 100A | * Least of 50 amps per 100 Ah battery or Controller Max | Charger enabled | true | | Battery preset | User | | Expert mode | false | | Absorption voltage | 14.40V | | Float voltage | 13.50V | * Not needed but keep below 13.6 | Equalization voltage | Disabled | * 13 if cant disable | Automatic Equalization | Disabled | | Temperature compensation | Disabled | | Low temperature cut-off | 41F | |--------------------------|----------| | SmartBMV | 712 | |--------------------------|----------| | Battery capacity | 200Ah | | Charged Voltage | 14.2V | | Discharge floor | 20% | | Tail Current | 4.00% | | Charged detection time | 3m | | Peukert exponent | 1.05 | | Charge efficiency factor | 99% | | Current threshold | 0.10A | | Time-to-go averaging per | 3m | | Battery SOC on reset | to 100% | | Relay mode | Default | | Invert relay | false | | Minimum close time | 0m | | Relay off delay | 0m | | Low SOC relay | 5% | | Clear low SOC relay | 10% | | Low voltage relay | 11V | | Clear low voltage relay | 12.5V | | High voltage relay | 14.8V | | Clear high voltage relay | 14.4V | | 50Ah 12V LeadAcid | 1x | |--------------------------|----------| | SmartSolar | MPPT | |--------------------------|----------| | Rotary switch | 2 | | Battery voltage | 12V | | Max charge current | 50 | | Charger enabled | true | | Battery preset | User | | Expert mode | false | | Absorption voltage | 14.25V | | Float voltage | 13.5 | | Equalization voltage | Disabled | * 13 if cant disable | Automatic Equalization | Disabled | | Temperature compensation | Disabled | | Low temperature cut-off | 41F | |--------------------------|----------| | SmartBMV | 712 | |--------------------------|----------| | Battery capacity | 50Ah | | Charged Voltage | 12.6V | | Discharge floor | 50% | | Tail Current | 4.00% | | Charged detection time | 3m | | Peukert exponent | 1.25 | | Charge efficiency factor | 95% | | Current threshold | 0.10A | | Time-to-go averaging per | 3m | | Battery SOC on reset | to 100% | | Relay mode | Default | | Invert relay | false | | Minimum close time | 0m | | Relay off delay | 0m |